(Air-breathing) Very Early Fire Particle Detector TL-XF001/Q

Scan QR code

Product Name:(Air-breathing) Very Early Fire Particle Detector TL-XF001/Q

The development of a fire can be divided into four stages: the first is the initial ignition stage: low heat, a small amount of smoke, and no flame can be observed; the second is the development stage, accompanied by an increase in heat, a large a...

Enquiry Back

The development of a fire can be divided into four stages: the first is the initial ignition stage: low heat, a small amount of smoke, and no flame can be observed; the second is the development stage, accompanied by an increase in heat, a large amount of smoke is generated, and the flame spreads; the third is the full development stage of the fire, at this time a large amount of heat and smoke is generated, and the flame expands over a large area; the last is the decay stage, when the flame and heat decrease and a large amount of smoke is generated.

In the past, due to the limitations of detection technology, conventional fire alarm systems mostly detected fires that were already in the development stage, because at this time, the burning of materials produced visible smoke, and then an alarm signal could be issued.

In the early stage of a fire (overheating, smoldering, or invisible smoke generation stages such as low thermal radiation and aerosol generation), by actively extracting air samples from the protected area and filtering them, the laser sensor collects tiny smoke particles generated by the combustion and exceeds the alarm threshold, and an alarm will be issued immediately. The system has extremely high sensitivity and a wide sensitivity adjustment range, which is commonly 0.002% to 20% OBS/m, while the sensitivity of traditional smoke detectors is only 3% to 5% OBS/m.

The detector uses an air pump to sample the air in the fire compartment through a sampling tube. The air sample is sent to the host and analyzed by a laser gun inside the host to obtain the concentration of smoke particles in the air. If the predetermined concentration is exceeded, the host will alarm. Multi-level warning: general hidden dangers, serious hidden dangers, and alarms. The highly sensitive laser sensor has a 360-degree range to receive scattered light generated by laser irradiation on smoke particles. Its actual sensitivity is 0.001% obs/m, which is 2000 times that of traditional detectors. It consists of an air sampling detector, an air sampling tube, a capillary sampling kit, a power box, a dedicated host for air sampling, etc.

Advanced technology: Optical cloud technology can detect nano-scale pyrolysis particles, abandoning traditional shading rate technology.

Non-contact: Active air suction sampling technology.

No blind spot: 360-degree three-dimensional full coverage from inside to outside.

Visualization: Using a 7-inch touch screen, the particle concentration data curve is displayed in real time.

Support multiple communication methods: MODBUS-485, 4G, Lora, Ethernet, optical fiber (optional)

Very early: Accurately detect the number of pyrolysis particles and issue alarm information very early before smoke and fire appear.

Anti-interference: 100% accurate and error-free alarm, avoiding the influence of environmental factors such as dust, strong light, airflow, water mist, etc.

Linkage output: Multi-level alarm linkage, which can be linked to sound and light alarms, smart buildings, fire alarm hosts, sprinklers, cameras, etc.

Open communication protocol output, docking and uploading to third-party platforms

Alarm output: multiple sets of relay dry contacts

Working environment temperature -20-+70

Working temperature: 10-95%RH

Product volume: 200*300*150

Four sets of high-sensitivity smoke detectors, independent detection and display in each zone.

The system is equipped with an embedded parameter setter as standard, which can set relevant parameters within the system.

Large-range partition protection, single tube maximum 60m, four-tube total length maximum 240m.

Each sampling tube has an independent airflow sensor, 1-4 channels are optional.

Protection area 1200-2000 square meters (optional according to different channels)

Independent or networked use, with extremely high flexibility and reliability, large space warehouses, power room, data center room, gymnasium, museum, chemical industry, battery cabinet, museum and other places. Very early detection and warning.

 